What do UL 94 V-0, V-1 and V-2 mean for plastic parts?

By Lianto Plastics

UL 94 is a small-scale test that classifies how a plastic material burns. In the vertical ratings V-0, V-1 and V-2, a specimen must stop flaming within a set time after the flame is removed, with V-0 the strictest. The rating applies to a material grade at a stated thickness and colour, not to a finished product.

UL 94 V-0, V-1 and V-2 are vertical flame classifications that measure how quickly a plastic specimen stops burning after a flame is removed and whether flaming drips ignite cotton underneath. V-0 sets the shortest flaming limit and bars cotton ignition, V-1 allows longer burning while still barring cotton ignition, and V-2 allows both. Each classification applies to a specific resin grade at a stated wall thickness and colour, not to an assembled part.

What is the UL 94 flammability rating?

UL 94 groups plastics into 12 flammability classifications from small-scale flame tests. Six apply to rigid plastics used for enclosures, structural parts and insulators: HB, V-2, V-1, V-0, 5VB and 5VA.

In that rigid group, HB uses a horizontal test, while V-2, V-1 and V-0 test vertical specimens. Both 5VB and 5VA use a flame about five times more severe than HB and the V ratings. Three foam classes (HBF, HF-2 and HF-1) and three thin-film classes (VTM) make up the rest of the standard.

What is the difference between UL 94 V-0, V-1 and V-2?

V-0, V-1 and V-2 differ on how long a vertical specimen may keep flaming after each flame application and whether flaming particles may ignite cotton placed below.

UL 94 ratingMaximum afterflame per flame applicationCotton indicator ignition by flaming drips
V-0Up to 10 secondsNot allowed
V-1Up to 30 secondsNot allowed
V-2Up to 30 secondsPermitted

Each vertical test records whether the specimen stops burning within the set time and whether flaming particles ignite a cotton indicator below. V-0 caps afterflame at 10 seconds after either flame application, while V-1 and V-2 allow up to 30 seconds, with cotton ignition permitted only in V-2.

In the vertical test a vertical specimen is exposed to a 20 mm flame in two applications of 10 seconds each, and afterflame time is measured after each one. Additional criteria, including total afterflame time and afterglow, also apply before a grade qualifies. Because these are laboratory results on a small specimen, they are best read as a way to compare materials rather than as a guarantee of how a finished case or bracket behaves in a real fire.

Does a UL 94 V-0 rating make a finished product fire-safe?

No, a UL 94 V-0 rating does not prove a component or finished product is fire-safe. UL 94 is a small-scale material classification carried out on the raw resin, so it does not show how an assembled product behaves in a fire.

For parts such as electronics cases, lids and brackets, treat UL 94 as one material specification alongside the rest of your product requirements.

Why do wall thickness and colour matter for a UL 94 rating?

A UL 94 classification applies only to a recognised material grade at the tested minimum thickness and colour coverage. One plastic can hold several classifications depending on wall thickness, so UL 94 information is only meaningful when wall thickness is stated alongside it.

A rating established at a thicker section cannot simply be transferred to a thinner design, so the rating you specify needs to match the moulding's main wall. A resin maker's datasheet shows the pattern: one PC/ABS flame-retardant grade is listed as UL 94 V0 at 0.75 mm, 5VA at 3.0 mm and 5VB at 1.5 mm, so each rating comes with its own thickness. Check the resin's UL Yellow Card to verify the supplier, grade, minimum thickness and colour coverage.

Wall thickness also governs how the plastic fills the mould, since recommended wall thickness depends on the flow behaviour of the material, including viscosity, crystallisation, fibre fill and additives. Reviewing sections early during design for manufacturing ensures the main wall satisfies both moulding flow and the UL 94 minimum.

Which injection moulding plastics come in UL 94 flame-retardant grades?

UL 94 V-0, V-1 and V-2 flame-retardant grades are available among the resins used for injection moulding. Lianto moulds ABS, PC, PP, PA66 (nylon), PC/ABS, glass-filled and specialty grades, including UL 94 V-0, V-1 and V-2 flame-retardant materials.

A flame rating belongs to a specific supplier grade, thickness and colour, not a whole resin family. When choosing the best plastic for injection moulding, confirm the exact grade and main wall thickness at quote stage, along with any Pantone or RAL colour match from a sample and any UV stability test requirement.

What should you tell a moulder when you need a flame-retardant plastic part?

Include four details at quote stage: the UL 94 rating, the main wall thickness, the colour and the end use. Send them with STEP, IGES, STL, X_T, PDF or DWG files (or sketches and photos of an existing part), and request an NDA first if required.

Tell us the UL 94 rating, the main wall thickness and the colour you need, so the resin grade can be checked before any steel is cut. First samples typically arrive 25 to 45 days after design confirmation with a measurement report and photos, and production starts about 10 days after sample approval. Each quotation sets out the full timeline.

Design, engineering and 3D printed proofs are done in Australia, and production happens in our partner factory. Send your files, rating, wall thickness and colour through our quote form, or call 1300 214 070.

Questions

What is the difference between UL 94 V-0 and V-2?

V-0 requires the specimen to stop flaming within 10 seconds after each flame application and does not allow flaming drips to ignite the cotton indicator. V-2 allows up to 30 seconds and permits cotton ignition.

Is UL 94 V-0 the same as fireproof?

No. UL 94 classifies how a material burns in a small-scale test. It does not show that a finished product is fire-safe.

Does a UL 94 rating depend on wall thickness?

Yes. A rating applies to a material grade at a stated minimum thickness and colour, so a rating at a thick section cannot be assumed for a thinner wall.

Can Lianto Plastics mould flame-retardant parts?

Lianto moulds in UL94 V-0, V-1 and V-2 flame-retardant grades. Tell us the rating, wall thickness and colour you need when you ask for a quote.

Sources

  1. Combustion (Fire) Tests for Plastics, UL Solutions

  2. Flammability of Polymer Materials and UL94 Explained, Passive Components

  3. Flame retardance of plastics: UL 94, BOPLA

  4. CYCOLOY FR resin CX7240 technical datasheet, SABIC

  5. Wall thickness in injection moulded parts, Envalior

Got an idea or a drawing?

Send it through for an engineering review and a fixed quotation.